Easy Connect | Power Options
White battery icon showing charging bars

1000 Backup Power Inverter & Batteries

The Model 1000 Power Inverter provides backup power for a single-gated Access Control System when primary AC power fails. With the 1000 Power Inverter & Batteries, properties can maintain a fully operational Access Control System during power outages and brown-outs

White battery icon showing charging bars

1000 Backup Power Inverter & Batteries

No Power? No Problem

DoorKing’s 1000 Power Inverter is designed to provide backup power for your Gate Operator and/or additional Access Control devices when primary (AC) power fails. Unlike DC Gate Operators that can only backup the Gate Operator itself with internal batteries to run the DC motor, the 1000 Power Inverter converts DC battery power to AC power to keep all Access Control components, even those that are powered by AC Accessory Transformers, operable at all times. DC Gate Operators do not convert their battery power to AC, which renders all the additional AC-powered components of an Access Control System inoperable during a power outage or brownout.

The 1000 Power Inverter & Batteries provide reliable backup power for most aspects of an Access Control System, including Gate Operators operating a single gate, Loop Detectors, Secondary Entrapment Devices, Entry Systems, Card Access Systems, RF Controls, Traffic Control Devices, and other components.

Entry accessory device with adjacent battery icon, indicating additional power considerations
Backup Power for Entire Access Control System
Silhouette of a horse with "HP" label, representing horsepower capacity
Supports one 1HP or two 1/2HP Gate Operators
Two stacked battery icons, indicating dual-battery support with pure sine wave inverter.
Pure Sine Wave Inverter Includes 2 Batteries

Applications

Icon of a multi-story building with windows and a central entrance, representing apartment complexes and college residence halls.

Apartment Complexes & College Residence Halls

Icon of a factory building with a chimney, representing commercial and industrial properties.

Commercial & Industrial

Icon of a community gate with two houses, representing gated communities.

Gated Communities

Icon of two large residential buildings with multiple families, representing large multi-family residential properties.

Large Multi-Family Residential

Icon of a two-story building with retail space and apartments, representing mixed-use buildings.

Mixed Use Buildings

Icon of a parking structure with multiple levels, representing parking facilities.

Parking Facilities

Icon of a row of storage unit doors, representing self-storage facilities.

Self Storage

Icon of a single house with a family, representing single-family residential homes.

Single Family Residential

Icon of a small residential building with two units and multiple families, representing small multi-family residential properties.

Small Multi-Family Residential

Product Compatibility

How It Works

Every Access Control System has unique power requirements, please consult with a DKS Dealer to understand the power requirements of your System and determine the backup power runtime for all components. The illustration below is an example of an Access Control System that will run for approximately X TIME PERIOD in a light duty setting.

Features

Diagram showing DKS power inverter connected to an access control system, gate operator, and entry device, illustrating complete backup coverage.

Whole System Power Backup

The 1000 is designed to run an entire Access Control System during power outages.

Illustration of a DC battery converting power to two AC outputs, highlighting the inverter’s ability to power 120V AC components.

Powers All AC Components

The Inverter converts the 12 Volt DC Battery power to 120 Volt AC.

Two battery icons, one partially and one fully charged, representing the inverter’s function of maintaining battery levels during normal use.

Maintains a Battery Charge

The Batteries charge during normal operation.

Interior view of the inverter cabinet showing two installed 35 Amp Hour SLA batteries and electronic components.

Two Batteries Included

Two included 35 Amp Hour SLA Batteries fit inside the cabinet.

Technical Specifications

DKS Cloud logo icon with the text “Compatible with Cloud Account Manager” indicating system compatibility with DKS's remote cloud-based management platform.

Compatible with Cloud Account Manager

DKS eVolve cloud icon with the text “Compatible with eVolve Cloud Account Manager,” indicating support for remote management of eVolve Series Entry Systems.

Compatible with eVolve Cloud Account Manager

1830s Remote Account Manager - Software - DKS Doorking

Compatible with Windows Account Manager

Folder icon with a downward arrow and "AP" label, indicating compatibility with Access Plus Windows Account Manager software.

Compatible with Access Plus Windows Account Manager

Mechanical
  • Pure Sine Wave Inverter can be used to power a single Gate Operator with a 1 HP motor, or 2 Gate
    Operators with 1/2 HP motors, and additional Access Control components.
  • Low Battery Alarm: 10.5 V
  • Low Battery Shutdown: 9.5 V
  • Overload Protection
  • Input Short Protection
  • Over Temperature Control (140°F / 60°C)
  • LED Status Indicators
  • Status Report Capability

    Control Circuit

  • Selectable Power Out and Power Start Options
  • Selectable Continuous Operation Mode or Quick Open Mode
  • Low Battery Shutdown and Operate Options
  • 2 Relays
  • Electronic control circuit monitors battery Voltage while System is in inverter mode and commands Gate Operators to open when battery power reaches critical levels.

IMPORTANT!  Use only with Gate Operators that utilize PSC motors.  Do not use with Operators that utilize motors with separate start and run windings.

Electrical
  • Continuous Power Output: 1000 Watts
  • Efficiency: 90%
  • Max AC Load Current: Pure Sine Wave = 12.5 A
  • DC Input Voltage: 10 to 15 VDC Nominal 12 VDC
  • Frequency: 60 Hz
  • AC Output Voltage: 120 VAC, 60 HzBatteries
  • Pure Sine Wave Inverter includes two Maintenance Free, Rechargeable, Non-spillable, Sealed
    Lead-Acid (SLA), 12-Volt, 35.0 Ah Batteries (wired in parallel).
  • Inverter Cabinet contains internal room for two Batteries.
Miscellaneous
  • Environmental Operating Temperature Range: 32°F to 104°F (0°C to 40°C)
  • Weight with two 35 Ah Batteries: approximately 83 lb (37.65 kg)
  • Additional 12-Volt, 35 Ah SLA Battery P/N 1801-005
Options
  • Post Mount Kit P/N 1000-045
  • Battery Cable Set P/N 1000-044
  • Additional 12-Volt, 35 Ah SLA Battery P/N 1801-005
Technical drawing showing front and side dimensions of the DKS inverter cabinet, measuring 13 inches wide, 21 inches tall, and 8 inches deep (330 mm x 533 mm x 203 mm).

1000 POWER INVERTER & BACKUP SYSTEM

OUTPUT WAVE FORM Pure Sine Wave

WATT

1000

BATTERIES INCLUDED

2 SLA 35 aH

POWERS

Two 1/2 HP operator or One 1 HP operator*

OUTPUT

120 VAC, 60 Hz

Tech Support

Find all the documentation needed to install, program, and operate your DKS product below.

Resources

1000 Power Inverter Literature
1000 Inverter/Backup Power Supply | Literature
Scroll to Top